FE Method of Analysing Detecting Electrode of Capacitance Proximity Fuze

  • The finite element method is first introduced into the design process of detecting electrodes of three electrode capacitance fuze, the mutual capacitance of the fuze and target is calculated by the finite element method, which provides the parameters for simulation circuit and design of detecting electrode. The finite element method pierces the traditional method of designing detecting electrode-design, test and adjustment. The system capacitance can be calculated accurately and the performance can be predicted in the design period of the detecting electrode, which saves a lot of research fee. The capacitances of a mortar shell fuze above ground 2 m and lower are given. After putting the computing data into simulating circuit, the demodulation voltage can be obtained, its changing trend is in agreement with the tested result.